General Information
The general tab shows the basic information and production performance of the plant.
This section contains summary information about the plant and production charts.
Plant Information
This panel contains the basic technical information of the plant.
Displayed information:
- Site Name: The site where the plant is located
- Plant Name: Plant name
- Plant Type: SPP, WPP, etc.
- Production Subscriber No: Production subscription number
- Consumption Subscriber No: Consumption subscription number
- Installed Power (kWp): Total installed capacity of the plant
- Connection Power (kWe): Maximum power delivered to the grid
Performance Indicators
The general tab contains summary information showing the plant performance.
Displayed metrics:
- Daily Production: Total energy produced by the plant during the day
- Monthly Production: Total energy produced during the selected month
- Yearly Production: Total energy produced throughout the year
- Availability: A performance metric showing the operational efficiency of the plant
- Revenue: Estimated income based on plant production
Production Chart
This chart shows the production performance of the plant throughout the day.
Three different data sets are displayed together in the chart:
- Power (kW)
- Radiation (Wh/m²)
- Temperature (°C)
With this chart, the relationship between solar radiation and production performance can be analyzed.
Electrical Measurement Charts
Electrical measurement data can also be displayed on the plant detail screen.
Displayed measurements:
Phase Voltages
- EKK Va
- EKK Vb
- EKK Vc
Phase Currents
- EKK Ia
- EKK Ib
- EKK Ic
These measurements are used to analyze the status of the grid connection.
Simulation Values
In this section, monthly production simulation data of the plant can be entered.
Simulation values are used for the following purposes:
- Expected production calculation
- Performance comparison
- Fault detection
- Efficiency analysis
Entered simulation values can be compared with actual production data.
Inverter Tab
This section is used to analyze the performance of inverter devices within the plant.
Inverter Operating Status
The production levels of inverters are shown with color codes:
- Low
- Medium Low
- Medium High
- High
- Maximum
This allows quick analysis of inverter performance.
Active Power Chart
This chart shows the instant power production of the inverters.
Each inverter is represented by a separate chart line.
With this chart:
- Inverter performance
- Production balance
- Fault detection
Inverter Daily Production
The daily production amount of each inverter is displayed.
This data is used for the following analyses:
- Inverter efficiency analysis
- Unbalanced production detection
- Performance comparison
MV Tab
The MV (Medium Voltage) tab shows electrical measurements on the MV side, which is the grid connection point of the plant.
Voltage Measurements
- Phase voltages
- Grid voltage fluctuations
Current Measurements
- Phase currents
- Load distribution
Power Values
- Active power
- Reactive power
- Apparent power
- Power factor
These measurements are used to analyze the grid compliance of the plant.
Alarms Tab
This section displays alarm records from plant devices.
- Alarm name
- Device
- Start time
- End time
- Priority
- Status
This allows plant operations to be monitored and faults to be detected quickly.
OSOS Tab
The OSOS tab shows meter data provided by the Electricity Distribution Company.
With the OSOS system, the following information can be displayed:
- Subscriber number
- Serial number
- Etso number
- Meter information
- Address information
- Subscriber type
OSOS data is used in energy consumption and netting calculations.
Purpose of the Plant Detail Page
The plant detail page is used for the following purposes:
- Plant performance tracking
- Production analysis
- Electrical measurement analysis
- Fault detection
- Energy revenue analysis
- Operational monitoring
This page is used as the operations center of the SolarMetrica platform.